The Advantages of Segmental Box Culvert

Segmental Box Culvert, Type 1

10' wide x 6' high Type I box culvert with 90-degree turn radius, custom manway accesses and lateral penetrations.  City North Project, Phoenix ArizonaDouble-cell 10' wide x 6' high Type I box culvert, Pinnacle Peak & Tatum intersection drainage improvements, City of Phoenix.
  • Meets ASTM C1786 Standard Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD
  • 4’ to 24’ spans, up to 8’ heights
  • Skewed ends for channel alignments, radius turns or angled turns
  • Longer lay-lengths, up to 16’
  • Faster installation using vertical gravity joint system
  • Accommodates lateral pipe penetrations & accesses
  • Cooper E-80, FAA AC150, AASHTO, and ACI 318 designs available

Segmental Box Culvert, Type 2 

Extending existing cast-in-place channel with precast reinforced concrete box culvert on I-10 in Pinal County, Arizona for the Arizona Department of Transportation (ADOT) using a double-cell 10' wide x 7' High Type II box culvert with skewed-end sections to match existing channel alignment.Type II 16' wide x 12' high center box culvert cell adjoined with two 12' wide x12' high end cells, El Mirage Rd. Phase B Project, El Mirage, Arizona.
  • Meets ASTM C1786 Standard Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD
  • 4’ to 24’ spans, up to 16’ heights
  • Skewed ends for channel alignments, radius turns or angled turns
  • Longer lay-lengths, up to 16’
  • Faster installation using vertical gravity joint system
  • Accommodates lateral pipe penetrations & accesses
  • Cooper E-80, FAA AC150, AASHTO, and ACI 318 designs available
Sort by
Show

Segmental Box Culvert, 14'-24' Span - Type 1

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available
Call for Availablility

Segmental Box Culvert, 14'-24' Span - Type 2

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available
Call for Availablility

Segmental Box Culvert, 14'-24' Span, Type 3

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available
Call for Availablility

Segmental Box Culvert, 4'-12' Span - Type 1

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available
Call for Availablility

Segmental Box Culvert, 4'-12' Span - Type 2

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available
Call for Availablility

Segmental Box Culvert, 4'-12' Span - Type 3

Availability:
FON | FRE | HON | JWR | LAS | LKS | LOC | MET | MTZ | ORL | PHX | SAC | SPA | TUC
Available